05.08
Remedy
F30640
Response
Acknowledgement
Explanation
Remedy
F30649
Response
Acknowledgement
Explanation
Remedy
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Select safe standstill and then deselect again.
– Check the motor holding brake connection.
– Check the function of the motor holding brake.
– Check whether there is a DRIVE–CLiQ communications error
between the Control Unit and the Motor Module involved and if
required, carry out a diagnostics routine for the faults identified.
– Check the electrical cabinet design and cable routing for EMC com-
pliance.
– Replace the Motor Module involved.
SI MM: Fault in the shutdown path of the control
OFF2
IMMEDIATELY (POWER ON)
The Motor Module has a detected a communications error with the
higher–level control to transfer information to shutdown.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Check the PROFIsafe address in the higher–level control and Motor
Module.
– Carry out a POWER ON for all components.
– Upgrade the Motor Module software.
SI MM: Internal software error
OFF2
IMMEDIATELY (POWER ON)
An internal error in the Safety Integrated software on the Motor Module
has occurred.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, hexadecimal):
Only for internal Siemens troubleshooting.
Carry out a POWER ON (power off/on) for all components.
– Re–commission the Safety Integrated function and carry out a
power on.
– Upgrade the Motor Module software.
– Contact the Hotline.
– Replace the Motor Module.