Siemens SINUMERIK 840D sl Function Manual page 375

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
DB 18
DBB150
to
DBB157
DBB158
to
DBB188
SPL status signals for DB18.DBW136
DB18.DBX136.0
DB18.DBX136.1
DB18.DBX136.2
DB18.DBX136.3
DB18.DBX136.4
DB18.DBX136.5
DB18.DBX136.6
DB18.DBX136.7
DB18.DBX137.0
DB18.DBX137.1
DB18.DBX137.2
DB18.DBX137.3
DB18.DBX137.4
DB18.DBX137.5
DB18.DBX137.6
DB18.DBX137.7
Table 8-9
Overview of DB 18 signals
DB18
Signal
r – read
w – write
Parameterization part
INSEP_VALID[1..8]
r/w
(no significance)
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Signals for safety SPL
SPL_STATUS[1]
NCK–SPL interfaces parameterized
SPL_STATUS[2]
NCK–SPL program file exists
SPL_STATUS[3]
NCK waits for the PLC to boot
SPL_STATUS[4]
NCK and PLC in cyclic operation
SPL_STATUS[5]
Call FB4 processing for SPL
SPL_STATUS[6]
End FB4 processing for SPL
SPL_STATUS[7]
Call FC9 processing for SPL
SPL_STATUS[8]
End FC9 processing for SPL
SPL_STATUS[9]
SPL start implemented using PROG_EVENT
mechanism
SPL_STATUS[10]
Crosswise data comparison started, NCK
SPL_STATUS[11]
Crosswise data comparison started, PLC
SPL_STATUS[12]
NCK–SPL checksum checking active
SPL_STATUS[13]
All SPL protective mechanisms active
SPL_STATUS[14]
End of SPL program reached
SPL_STATUS[15]
Not assigned
SPL_STATUS[16]
Not assigned
Type
Value range
Bool
Data Description
8.3 Interface signals
Comment
0 = INSEP[1..8] No automatic transfer,
can be supplied from the user pro-
gram (AWP)
1 = Transfer of input byte, specified in
INSEP_ADDR[1..8] to INSEP[1..8] by
the basic program
8-375

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents