05.08
Q1
Q2
TM1
CMP
>=
E1
AND
I2
E3
TI1
TI2
TI3
Fig. 7-23
Function diagram of the "safety relay"
The description is provided in the following:
Three shutdown inputs E1 to E3
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
OR
AND
Time measurement –
rising to falling edge
t4
E_AND
If one of these inputs is set to 0, direct output A0 is set
to 0. Outputs A1 toA3 switch with the delay of timer
1–3. If one of these inputs is not used, then it is inter-
nally set to "1" as static signal.
One of these inputs must also be used to initiate test
operation of the safety relay (forced checking proce-
dure).
Connecting Sensors/Actuators
7.3 Safe programmable logic (SPL)
AND
t4i
A0
A1
Timer1
A2
Timer2
A3
Timer3
7-237