Diagnostics

Note
Not all of the HMI functions shown are available in all of the HMI versions (HMI
Embedded, HMI sl, HMI Advanced).
10.1
Troubleshooting procedure
S The alarms that have been activated in response to an error are output in the
"DIAGNOSIS – ALARMS" display. When required, the safety alarms can be
suppressed in the diagnostics display using the "Filter out SI alarms" softkey.
S For Alarm 27090 "Error for crosswise data comparison NCK–PLC", the cause of
the error (the incorrect SPL variable) is displayed in the alarm output.
S For Alarm 27254 "PROFIsafe: F module, error on channel", the input/output
channel with error for modules belonging to the ET 200 series, is displayed in
the alarm output.
S For Alarm 27001 "Defect in a monitoring channel", the fine error code is also
displayed in the alarm output.
S For Alarm C01711 "SI motion defect in a monitoring channel" the fine error code
is displayed in the alarm output. In the screen "Commissioning – machine data
– drive MD", using parameter r9725: "SI motion diagnostics STOP F", the
cause of the alarm can be read out.
S The current crosswise data comparison error code of the drive monitoring chan-
nel is displayed in the diagnostics screen "Status SI" in line "Stop F code value".
S For Alarms F01611/F30611 "Defect in a monitoring channel", the fine error code
is displayed in the alarm output. The current error search of this alarm is addi-
tionally displayed in parameters r9795/r9895.
Note
Different error codes may be displayed for the NCK and drive monitoring channels.
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition