Siemens SINUMERIK 840D sl Function Manual page 344

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data Description
8.2 Parameters for SINAMICS S120
r9735[0...1]
SI motion, diagnostics result list 3
Displays result list 3 where for a crosswise data comparison with the control,
led to an error.
[0]: Result list second channel
[1]: Result list drive
Bit field
Bit 00
Actual value > Upper limit SN1+
Bit 01
Actual value > Lower limit SN1+
Bit 02
Actual value > Upper limit SN1–
Bit 03
Actual value > Lower limit SN1–
Bit 04
Actual value > Upper limit SN2+
Bit 05
Actual value > Lower limit SN2+
Bit 06
Actual value > Upper limit SN2–
Bit 07
Actual value > Lower limit SN2–
Bit 08
Actual value > Upper limit SN3+
Bit 09
Actual value > Lower limit SN3+
Bit 10
Actual value > Upper limit SN3–
Bit 11
Actual value > Lower limit SN3–
Bit 12
Actual value > Upper limit SN4+
Bit 13
Actual value > Lower limit SN4+
Bit 14
Actual value > Upper limit SN4–
Bit 15
Actual value > Lower limit SN4–
Bit 16
Actual value > Upper limit SN5+
Bit 17
Actual value > Lower limit SN5+
Bit 18
Actual value > Upper limit SN5–
Bit 19
Actual value > Lower limit SN5–
Bit 20
Actual value > Upper limit SN6+
Bit 21
Actual value > Lower limit SN6+
Bit22
Actual value > Upper limit SN6–
Bit23
Actual value > Lower limit SN6–
See also: C01711
Unit:
Default value:
8-344
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
Checksum:
Protection level:
Yes
3
Data type:
Effective:
POWER ON
Unsigned32
© Siemens AG 2008 All Rights Reserved