8.1 Machine data for SINUMERIK 840D sl
13301
MD number
Default value 0xFFFFFFFF
Change becomes effective after: POWER ON
Data type: DWORD
Significance:
corresponds with ...
Additional references
13310
MD number
Default value 20.
Change becomes effective after: POWER ON
Data type: DOUBLE
Significance:
corresponds with ...
Additional references
8-274
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
$MN_PROFISAFE_OUT_FIL TER
F net (useful) data filter OUT
Min. input limit: –
Protection level: 7/2
Filter between $A_OUTSE variables and F net (useful) data
The machine data: PROFISAFE_OUT_ASSIGN is used to define which $A_OUTSE[n]
variables are transferred into the F net data bits of the PROFIsafe module.
The machine data: PROFISAFE_OUT_FILTER is used to define which F net data bit is
transferred to the particular $A_OUTSE[n] variable.
Example:
Note: For reasons of simplicity, only 16 bits are taken into consideration.
Parameter assignment:
$MN_PROFISAFE_OUT_FIL TER = 1010100101000100
$MN_PROFISAFE_OUT_ASSIGN = 011006
n = 16
11
6
1
xxxx x111 111x xxxx
0000 0000 0011 1111
1010 1001 0100 0100
1010 1001 0100 0100
$MN_SAFE_SPL_ST ART_TIMEOUT
Delay, display Alarm 27097
Min. input limit: 1.
Protection level: 7/2
After the control has booted, after the time has expired, Alarm 27097 is displayed if there
was no SPL start.
Max. input limit: –
example value in the $OUTSE variables, x not relevant
internal NCK F net data image
$MN_PROFISAFE_OUT_FIL TER
F net data of the PROFIsafe module
Max. input limit: 60.
© Siemens AG 2008 All Rights Reserved
05.08
Unit: –
Unit: s