r9736[0...1]
SI motion, diagnostics result list 4
Displays result list 4 where for a crosswise data comparison with the control,
led to an error.
[0]: Result list second channel
[1]: Result list drive
Bit field
Bit 00
Actual value > Upper limit SN7+
Bit 01
Actual value > Lower limit SN7+
Bit 02
Actual value > Upper limit SN7–
Bit 03
Actual value > Lower limit SN7–
Bit 04
Actual value > Upper limit SN8+
Bit 05
Actual value > Lower limit SN8+
Bit 06
Actual value > Upper limit SN8–
Bit 07
Actual value > Lower limit SN8–
Bit 08
Actual value > Upper limit SN9+
Bit 09
Actual value > Lower limit SN9+
Bit 10
Actual value > Upper limit SN9–
Bit 11
Actual value > Lower limit SN9–
Bit 12
Actual value > Upper limit SN10+
Bit 13
Actual value > Lower limit SN10+
Bit 14
Actual value > Upper limit SN10–
Bit 15
Actual value > Lower limit SN10–
Bit 16
Actual value > Upper limit SN11+
Bit 17
Actual value > Lower limit SN11+
Bit 18
Actual value > Upper limit SN11–
Bit 19
Actual value > Lower limit SN11–
Bit 20
Actual value > Upper limit SN12+
Bit 21
Actual value > Lower limit SN12+
Bit22
Actual value > Upper limit SN12–
Bit23
Actual value > Lower limit SN12–
See also: C01711
Unit:
Default value:
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
Data Description
8.2 Parameters for SINAMICS S120
Checksum:
Yes
Data type:
Unsigned32
Protection level:
3
Effective:
POWER ON
8-345

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents