Siemens SINUMERIK 840D sl Function Manual page 278

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Data Description
8.1 Machine data for SINUMERIK 840D sl
36905
MD number
Default value: 0.0
Change becomes effective after: POWER ON
Data type: DOUBLE
Significance:
Special cases, errors,...
corresponds with ...
Additional references
36906
MD number
Default value: 1, 2, 3..
Change becomes effective after: POWER ON
Data type: BYTE
Significance:
Special cases, errors,...
corresponds with ...
8-278
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
$MA_SAFE_MODULO_RANGE
Modulo value, safe cams
Min. input limit: 0.0
Protection level: 7/2
Actual value range within which safe cams for rotary axes are calculated. The axis must be
a rotary axis ($MA_SAFE_IS_ROT_AX = 1).
0:
Modulo correction after +/– 2048 revolutions (i.e. after 737 280 degrees)
> 0 and multiples of 360 Degrees:
Modulo correction after this value e.g. value = 360 degrees –> the actual value range is
between 0 and 359.999 degrees, i.e. a modulo correction is carried out after every revolu-
tion.
If the value set in this data is not 0 or a multiple of 360 degrees, then an appropriate
alarm is output when the system boots.
The cam positions are also checked with respect to the parameterized actual value
when the system boots. An appropriate alarm is output if parameterization errors are
detected.
Actual value ranges set in $MA_SAFE_MODULO_RANGE and $MA_MO-
DULO_RANGE must be a multiple integer.
MD 30330: $MA_MODULO_RANGE
MD 36935: $MA_SAFE_CAM_POS_PLUS[n]
MD 36937: $MA_SAFE_CAM_POS_MINUS[n]
/FBSI/ see Chapter 6.8: "Safe software cams, safe cam track (SN)"
$MA_SAFE_CTRLOUT_MODULE_NR
SI drive assignment
Min. input limit: 1
Protection level: 7/2
Index in the data array $MN_SAFE_DRIVE_LOGIC_ADDRESS to assign the drive for SI
motion monitoring functions.
The same drive must be assigned that was also selected using CTRLOUT_MODULE_NR
and DRIVE_LOGIC_ADDRESS.
Max. input limit: 737280.0
Unit: degrees
Max. input limit: 31
Unit: –
© Siemens AG 2008 All Rights Reserved
05.08

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents