Data Description
8.2 Parameters for SINAMICS S120
r9756[0...63]
SI message time removed in days
Displays the relative system runtime in days when the safety message was
removed.
See also r9744, r9747, r9748, r7949, p9752, r9753,r9754, r9755, p9759
Unit:
Default value:
days
p9759
SI acknowledge messages, drive object
Acknowledges all safety messages present for a drive object.
Parameter should be set from 0 to 1 to acknowledge. After acknowledgement,
the parameter is automatically reset to 0.
See also r9744, r9747, r9748, r7949, p9752, r9753,r9754, r9755, p9759
Unit:
Default value:
0
p9761
SI password input
Enters the Safety Integrated password. It is not permissible to change Safety
Integrated parameter settings until the Safety Integrated password has been
entered.
Unit:
Default value:
0000 hex
See also: F01659 "SI CU: Write task for parameter rejected"
p9762
SI password, new
Enters a new Safety Integrated password. If the Safety Integrated password is
changed it must be acknowledged in the following parameter:
See also: p9763
Unit:
Default value:
0000 hex
p9763
SI password acknowledgment
Acknowledges the new Safety Integrated password. The new password en-
tered into p9762 must be re–entered in order to acknowledge. After success-
fully acknowledged, the new Safety Integrated password is set with
p9762=p9763=0.
See also: p9762
Unit:
Default value:
0000 hex
8-350
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
Minimum value:
Maximum value:
0
1
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Minimum value:
Maximum value:
0000 hex
FFFF FFFF hex
Checksum:
Protection level:
3
Data type:
Effective:
Unsigned16
Checksum:
Protection level:
3
Data type:
Effective:
Unsigned8
Checksum:
Protection level:
No
3
Data type:
Effective:
Unsigned32
Immediately
Checksum:
Protection level:
No
3
Data type:
Effective:
Unsigned32
Immediately
Checksum:
Protection level:
No
3
Data type:
Effective:
Unsigned32
Immediately