Functions
8.18 Fail-safe functions
Caution
In SLS modes 0 and 1, the frequency setpoint can increase related to the following functions
• PID Trim
• Vdc max controller
• Slip compensation
• Resonance damping
• Imax
As the frequency is monitored after adding these values, this increasement should be taken
into account by the user when parameterising the safe frequency envelope.
*) If PID as trim is active when SS1, SLS0 or SLS1 is triggered, the PID as trim is
deactivated and has no influence to the frequency setpoint at the latest 1 s after the fail-safe
function has been activated.
8.18.6

Safe Brake Control

Data
Parameter range:
Warnings
Faults
Description
The Safe Brake Control function (SBC) is to create a fail-safe signal to control an
electromechanical motor brake.
8-136
+
+
P0003, P0010
P09761
P9601/P9801, P1215, P3046
P9602/P9802
P9799/P9899/P3900
A1691, A1692, A1696, A1699
F1600, F1616
+
-
Operating Instructions, 11/2006, A5E00766042B AA
+
Control Units CU240S