Conventional Acceptance Test - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
Table 9-1
Scope of the acceptance test depending on specific measures
Measure
Data transferred to
additional machines
with series commis-
sioning
Note: If the results of function test, Part 2 are taken from another identical machine, then this is the sole
responsibility of the machine manufacturer and should be appropriately commented in the acceptance
report.
9.5.2

Conventional acceptance test

Procedure of the conventional acceptance test
Safety function
Forced checking proce-
dure of the shutdown
paths
Sequence of the test
stop routine for external
stops
Forced checking proce-
dure of the input/output
peripherals (e.g. Emer-
gency Stop)
Configuring/hardware
configuration of the
PROFIsafe I/O
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Documentation
Function test
Part 1
Possibly sup-
Yes with note
plement, ma-
chine descrip-
tion (check the
SW version)
Test initiated by
Test stop initiated e.g.
by reducing the test stop
time or separate key
Switching operations at
the SGE/SGA
Test stop initiated e.g.
by reducing the test stop
time or separate key
Test stop initiated e.g.
by reducing the test stop
time or separate key
SPL
Function test
Part 2
No, for identical
data
Function checked
using
Alarm log
Diagnostics display
Servo trace SGE/SGA
Servo trace SGE/SGA
Diagnostics display
Drive interface PLC
Disconnect the feed-
back signal contacts or
jumper an SPL input
Diagnostic displays,
behavior of the SPL and
I/O terminals, printout of
the hardware configura-
tion from SIMATIC
Step 7
Commissioning
9.5 Acceptance test
Report
completion
No
No, if identical
data (check the
checksums)
Represented using
27002 axis
Test stop running
C01798 test stop run-
ning (this is not abso-
lutely required)
Diagnostics screen SI
status
Decoded using servo
trace bit graphics
De–coded using servo
trace bit graphics
Diagnostics screen SI
status
Trace Sinucom NC trace
User error message
Stop D is initiated
Printout of the hardware
configuration from
SIMATIC Step 7
9-419

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics s120

Table of Contents