Siemens SINUMERIK 840D sl Function Manual page 528

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Diagnostics
10.2 NCK safety alarms for SINUMERIK 840D sl
27206
Parameter
Explanation
Response
Remedy
Program
continuation
27207
Parameter
Explanation
Response
Remedy
Program
continuation
10-528
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
PROFIsafe: MD %1[%2] max. number of F net data (%3 bits)
exceeded
%1 MD name
%2 MD field index to the MD name
%3 F net data bits
Data parameterized in the specified machine data lie outside the F net
(useful) data area of the F module.
Note:
When displaying machine data PROFISAFE_IN/OUT_ADDRESS, the
sub–slot address parameterized in the machine data exceeds the F net
data area of the F module.
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Correct the MD.
Switch control system OFF and ON again.
PROFIsafe: MD %1[%2] max. sub–slot number: %3 exceeded
%1 MD name
%2 MD field index to the MD name
%3 max. number of sub–slots
The sub–slot parameterized in the specified machine data exceeds the
max. permissible number of sub slots per PROFIsafe module.
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Reduce the number of sub–slots by changing the F net (useful) data
distribution of the PROFIsafe module.
Switch control system OFF and ON again.
© Siemens AG 2008 All Rights Reserved