Connecting Sensors/Actuators
7.1 Safety–related input/output signals
IM 151–1
High Feature
PROFIBUS
with
PROFIsafe
Fig. 7-5
Actuator connection via fail–safe outputs, e.g. 400 V load circuit – P/M–switching
Example of connecting a sensor
2 safety–related inputs (to read–in through 2 channels via SGE) and 1 standard
test output (for the forced checking procedure) are required to connect a sensor in
a fail–safe fashion. The test output is fed from the power supply voltage of the
safety input module. For sensors with a self–test routine, the test output on the
input module is not required. For the 3–terminal connection concept we recom-
mend that sensors with non–equivalence contacts are used (NC contact/NO con-
tact). If a P or M short–circuit or broken cable at both signal cables, then a signal
state is obtained that is not logically permissible. This means, that a cross–circuit
fault can be detected by the non–equivalence concept without having to carry out
any test.
Note
Cross–circuit fault detection in the input module is not required.
7-192
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
F–DO
DI
Feedback
ET 200S PROFIsafe
Electronics output – M
24 V load
circuit,
indirect
400 V
Electronics output – P
© Siemens AG 2008 All Rights Reserved
05.08
Indirectly
position
monitoring of the load
using positively–driven
contacts