05.08
C01689
Response
Acknowledgement
Explanation
Remedy
A01698 (F)
Response
Acknowledgement
Explanation
Remedy
Response
Acknowledgement for F IMMEDIATELY (POWER ON)
A01699 (F)
Response
Acknowledgement
Explanation
Remedy
Response
Acknowledgement for F IMMEDIATELY (POWER ON)
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
SI motion: Axis re–configured
OFF2
POWER ON
The axis configuration was changed.
Parameter p0108. 13 is internally set to the corrected value.
Fault value (r0949, decimal):
Parameter number that initiated the change.
See also: p9502 (SI motion axis type)
Initiate data save on the complete Control Unit and carry out a POWER ON.
SI CU: Commissioning mode active
NONE
NONE
The commissioning of the "Safety Integrated" function is selected.
This message is withdrawn after the safety functions have been
commissioned.
Note:
This message does not result in a safety stop response.
See also: p0010 (infeed commissioning, parameter filter)
None necessary
NONE (OFF1, OFF2, OFF3)
SI CU: Shutdown paths must be tested
NONE
NONE
The time set in p9659 for the forced checking procedure of the safety
shutdown paths has been exceeded. The safety shutdown paths must
be re–tested.
After the next time that the function "safe standstill" (SH) is deselected,
the message is withdrawn and the monitoring time is reset.
Note:
This message does not result in a safety stop response.
See also: p9659 (SI forced checking procedure, timer)
Select safe standstill and then deselect again
NONE (OFF1, OFF2, OFF3)
10.3 Safety messages for SINAMICS S120