05.08
Remedy
F01612
Response
Acknowledgement
Explanation
Remedy
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Re fault value = 1 to 999:
– Check the crosswise compared data that resulted in a STOP F.
– Carry out a POWER ON (power off/on) for all components.
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.
Re fault value = 1000:
– Check the EP terminal at the Motor Module (contact problems).
Re fault value = 1001, 1002:
– Carry out a POWER ON (power off/on) for all components.
– Upgrade the Motor Module software.
– Upgrade the Control Unit software.
Re fault value = 2000, 2001, 2002, 2004, 2005:
– Check the tolerance time SGE changeover and if required, increase
the value (p9650/p9850, p9652/p9852).
– Check the wiring of the safety–related inputs (SGE) (contact
problems).
– Replace the Motor Module involved.
SI CU: STO inputs for power units connected in parallel different
NONE
IMMEDIATELY
The drive–autonomous function "Safety Integrated" on the Control Unit
(CU) has identified different states of the AND'ed STO inputs for power
units connected in parallel and has initiated a STOP F.
As a result of this fault, after the parameterized transition has expired
(p9658), fault F01600 (SI CU: STOP A initiated) is output.
Fault value (r0949, interpret as binary):
Binary image of the Control Unit digital inputs that are used as signal
source for the "Safe Torque Off" function.
– Check the tolerance time SGE changeover and if required, increase
the value (p9650).
Check the wiring of the safety–related inputs (SGE) (contact problems).
10.3 Safety messages for SINAMICS S120
Diagnostics
10-543