10.2 NCK safety alarms for SINUMERIK 840D sl
27240
Parameter
Explanation
Response
Remedy
Program
continuation
27241
Parameter
Explanation
Response
Remedy
Program
continuation
10-532
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
PROFIsafe: DP M has not run–up, DP info: %1
%1 = actual information from the DP interface NCK–PLC
There is no DP configuration available to the NCK after the time speci-
fied using the MD $MN_PLC_RUNNINGUP_TIMEOUT.
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Increase MD $MN_PLC_RUNNINGUP_TIMEOUT
Check the PLC operating state
Check the PLC operating system software release
Delete the F parameterization in the NCK–MD
Switch control system OFF and ON again.
PROFIsafe: DP M version different, NCK: %1, PLC: %2
%1 = version of the DP interface on the NCK side
%2 = version of the DP interface on the PLC side
The DP interface has been implemented differently for the NCK and
PLC components. The F communications cannot be initialized
Mode group not ready
Channel not ready
NC start inhibit in this channel
Interface signals are set
Alarm display
NC stop for alarm
Check the PLC operating system and correct NCK software versions.
Upgrade the PLC operating system.
Delete NCK F parameterization.
Switch control system OFF and ON again.
© Siemens AG 2008 All Rights Reserved