Acceptance Test/Configuration Test - Siemens PM330 Hardware Installation Manual

Sinamics g120p power module
Table of Contents

Advertisement

Appendix
A.4 Acceptance test/configuration test
A.4

Acceptance test/configuration test

The acceptance test checks that the safety subfunction implemented in the inverter has been
correctly set. Where necessary, the complete safety function can also be checked. The
following acceptance tests are examples which demonstrate the basic procedure. They are
not suitable for every possible setting of the inverter.
Recommendations for the acceptance test
● Perform the acceptance test with the maximum possible velocity and acceleration to test
the expected maximum braking distances and braking times.
● The trace function in the STARTER and Startdrive PC tools can simplify the acceptance
test in certain applications: for example, if a drive in the machine is difficult to access.
Therefore, we recommend that you use the trace function for some acceptance tests.
● If you have recorded a trace for an acceptance test, you have to proceed as follows:
– When you save the trace, enter the storage location in the acceptance report.
– If you print the trace, attach the printout to the acceptance report.
● If you can carry out the acceptance test without the trace function, there is no need to use
the trace.
● After the acceptance test of the inverter's safety functions, you must also check whether
the safety-related functions in the machine or system are functioning correctly.
134
Hardware Installation Manual, 12/2018, A5E32844552B AF