Settings; Setting Parameters For Binary Input Modules - ABB RET650 Technical Manual

Relion 650 series transformer protection
Hide thumbs Also See for RET650:
Table of Contents

Advertisement

Section 4
Binary input and output modules
4.1.3
4.1.3.1
Table 8:
BIO_9BI Non group settings (basic)
Name
BatteryVoltage
Table 9:
BIO_9BI Non group settings (advanced)
Name
Threshold1
DebounceTime1
OscillationCount1
OscillationTime1
Threshold2
DebounceTime2
OscillationCount2
OscillationTime2
Threshold3
DebounceTime3
OscillationCount3
OscillationTime3
Threshold4
DebounceTime4
OscillationCount4
OscillationTime4
Threshold5
DebounceTime5
OscillationCount5
OscillationTime5
Threshold6
DebounceTime6
OscillationCount6
Table continues on next page
52
Each binary input has an oscillation count parameter OscillationCountx and an
oscillation time parameter OscillationTimex, where x is the number of the binary input
of the module in question.

Settings

Setting parameters for binary input modules

Values (Range)
Unit
24 - 250
V
Values (Range)
Unit
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
Step
Default
1
110
Step
Default
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
1MRK 504 135-UEN A
Description
Station battery voltage
Description
Threshold in percentage of station battery
voltage for input 1
Debounce time for input 1
Oscillation count for input 1
Oscillation time for input 1
Threshold in percentage of station battery
voltage for input 2
Debounce time for input 2
Oscillation count for input 2
Oscillation time for input 2
Threshold in percentage of station battery
voltage for input 3
Debounce time for input 3
Oscillation count for input 3
Oscillation time for input 3
Threshold in percentage of station battery
voltage for input 4
Debounce time for input 4
Oscillation count for input 4
Oscillation time for input 4
Threshold in percentage of station battery
voltage for input 5
Debounce time for input 5
Oscillation count for input 5
Oscillation time for input 5
Threshold in percentage of station battery
voltage for input 6
Debounce time for input 6
Oscillation count for input 6
Technical manual