ABB RET650 Technical Manual page 60

Relion 650 series transformer protection
Hide thumbs Also See for RET650:
Table of Contents

Advertisement

Section 4
Binary input and output modules
Name
Threshold4
DebounceTime4
OscillationCount4
OscillationTime4
Threshold5
DebounceTime5
OscillationCount5
OscillationTime5
Threshold6
DebounceTime6
OscillationCount6
OscillationTime6
Threshold7
DebounceTime7
OscillationCount7
OscillationTime7
Threshold8
DebounceTime8
OscillationCount8
OscillationTime8
Threshold9
DebounceTime9
OscillationCount9
OscillationTime9
Threshold10
DebounceTime10
OscillationCount10
OscillationTime10
Threshold11
DebounceTime11
OscillationCount11
OscillationTime11
Threshold12
Table continues on next page
54
Values (Range)
Unit
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
0.000 - 0.100
s
0 - 255
-
0.000 - 600.000
s
6 - 900
%UB
Step
Default
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
0.001
0.005
1
0
0.001
0.000
1
65
1MRK 504 135-UEN A
Description
Threshold in percentage of station battery
voltage for input 4
Debounce time for input 4
Oscillation count for input 4
Oscillation time for input 4
Threshold in percentage of station battery
voltage for input 5
Debounce time for input 5
Oscillation count for input 5
Oscillation time for input 5
Threshold in percentage of station battery
voltage for input 6
Debounce time for input 6
Oscillation count for input 6
Oscillation time for input 6
Threshold in percentage of station battery
voltage for input 7
Debounce time for input 7
Oscillation count for input 7
Oscillation time for input 7
Threshold in percentage of station battery
voltage for input 8
Debounce time for input 8
Oscillation count for input 8
Oscillation time for input 8
Threshold in percentage of station battery
voltage for input 9
Debounce time for input 9
Oscillation count for input 9
Oscillation time for input 9
Threshold in percentage of station battery
voltage for input 10
Debounce time for input 10
Oscillation count for input 10
Oscillation time for input 10
Threshold in percentage of station battery
voltage for input 11
Debounce time for input 11
Oscillation count for input 11
Oscillation time for input 11
Threshold in percentage of station battery
voltage for input 12
Technical manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents