ABB RET650 Technical Manual page 420

Relion 650 series transformer protection
Hide thumbs Also See for RET650:
Table of Contents

Advertisement

Section 14
Monitoring
Name
QLimHyst
UGenZeroDb
PFDbRepInt
PFZeroDb
IGenZeroDb
PFHiHiLim
PFHiLim
PFLowLim
PFLowLowLim
PFLimHyst
UDbRepInt
UZeroDb
UHiHiLim
UHiLim
ULowLim
ULowLowLim
ULimHyst
IDbRepInt
IZeroDb
IHiHiLim
IHiLim
ILowLim
ILowLowLim
ILimHyst
FrDbRepInt
FrZeroDb
FrHiHiLim
FrHiLim
FrLowLim
FrLowLowLim
FrLimHyst
UAmpComp5
UAmpComp30
Table continues on next page
414
Values (Range)
Unit
0.000 - 100.000
%
1 - 100
%UB
1 - 300
Type
0 - 100000
m%
1 - 100
%IB
-1.000 - 1.000
-
-1.000 - 1.000
-
-1.000 - 1.000
-
-1.000 - 1.000
-
0.000 - 100.000
%
1 - 300
Type
0 - 100000
m%
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.0 - 200.0
%UB
0.000 - 100.000
%
1 - 300
Type
0 - 100000
m%
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.0 - 500.0
%IB
0.000 - 100.000
%
1 - 300
Type
0 - 100000
m%
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
Hz
0.000 - 100.000
%
-10.000 - 10.000
%
-10.000 - 10.000
%
Step
Default
0.001
5.000
1
5
1
10
1
500
1
5
0.001
1.000
0.001
0.800
0.001
-0.800
0.001
-1.000
0.001
5.000
1
10
1
500
0.1
150.0
0.1
120.0
0.1
80.0
0.1
60.0
0.001
5.000
1
10
1
500
0.1
150.0
0.1
120.0
0.1
80.0
0.1
60.0
0.001
5.000
1
10
1
500
0.001
65.000
0.001
63.000
0.001
47.000
0.001
45.000
0.001
5.000
0.001
0.000
0.001
0.000
1MRK 504 135-UEN A
Description
Hysteresis value in % of range (common
for all limits)
Zero point clamping in % of Ubase
Cycl: Report interval (s), Db: In % of
range, Int Db: In %s
Zero point clamping
Zero point clamping in % of Ibase
High High limit (physical value)
High limit (physical value)
Low limit (physical value)
Low Low limit (physical value)
Hysteresis value in % of range (common
for all limits)
Cycl: Report interval (s), Db: In % of
range, Int Db: In %s
Zero point clamping
High High limit in % of UBase
High limit in % of UBase
Low limit in % of UBase
Low Low limit in % of UBase
Hysteresis value in % of range (common
for all limits)
Cycl: Report interval (s), Db: In % of
range, Int Db: In %s
Zero point clamping
High High limit in % of IBase
High limit in % of IBase
Low limit in % of IBase
Low Low limit in % of IBase
Hysteresis value in % of range (common
for all limits)
Cycl: Report interval (s), Db: In % of
range, Int Db: In %s
Zero point clamping
High High limit (physical value)
High limit (physical value)
Low limit (physical value)
Low Low limit (physical value)
Hysteresis value in % of range (common
for all limits)
Amplitude factor to calibrate voltage at 5%
of Ur
Amplitude factor to calibrate voltage at
30% of Ur
Technical manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents