Ipv6 Nd Raguard Attach-Policy (Vlan Mode) - Cisco 300 Series Cli Manual

Stackable managed switches
Hide thumbs Also See for 300 Series:
Table of Contents

Advertisement

25
527
switchxxxxxx(config-if)#
switchxxxxxx(config-if)#
Example 3—In the following example, the RA Guard policy policy1 is attached to
the gi 1 1 port and applied to VLANs 1-10 and the RA Guard policy policy2 is
attached to the gi 1 1 port and applied to VLANs 12-20:
switchxxxxxx(config)#
switchxxxxxx(config-if)#
switchxxxxxx(config-if)#
switchxxxxxx(config-if)#
Example 4—In the following example RA Guard detaches policy policy1 from the
gi 1 1 port:
switchxxxxxx(config)#
switchxxxxxx(config-if)#
switchxxxxxx(config-if)# exit
25.32 ipv6 nd raguard attach-policy (VLAN
mode)
To attach an RA Guard policy to a specified VLAN, use the ipv6 nd raguard
attach-policy command in VLAN Configuration mode. To return to the default, use
the no form of this command.
Syntax
ipv6 nd raguard attach-policy
no ipv6 nd raguard attach-policy
Parameters
policy-name
—The RA Guard policy name (up to 32 characters).
ipv6 nd raguard attach-policy policy1 vlan 1-10,12-20
exit
interface gi11
ipv6 nd raguard attach-policy policy1 vlan 1-10
ipv6 nd raguard attach-policy policy2 vlan 12-20
exit
interface gi11
no ipv6 nd raguard attach-policy policy1
policy-name
OL-32830-01 Command Line Interface Reference Guide
IPv6 First Hop Security

Advertisement

Table of Contents
loading

Table of Contents