Clock Commands
OL-32830-01 Command Line Interface Reference Guide
recurring—Indicates that summer time starts and ends on the
corresponding specified days every year.
date—Indicates that summer time starts on the first date listed in the
command and ends on the second date in the command.
usa—The summer time rules are the United States rules.
eu—The summer time rules are the European Union rules.
week
—Week of the month. Can be 1–5, first to last.
day
—Day of the week (first three characters by name, such as Sun).
date
—Date of the month. (Range: 1–31)
month
—Month (first three characters by name, such as Feb).
year
—year (no abbreviation). (Range: 2000–2097)
hh:mm
—Time (military format) in hours and minutes. (Range: hh:mmhh: 0-23,
mm: 0-59)
offset
—(Optional) Number of minutes to add during summer time (default is
60). (Range: 1440)
Default Configuration
Summer time is disabled.
Command Mode
Global Configuration mode
User Guidelines
In both the date and recurring forms of the command, the first part of the command
specifies when summer time begins, and the second part specifies when it ends.
All times are relative to the local time zone. The start time is relative to standard
time. The end time is relative to summer time. If the starting month is
chronologically after the ending month, the system assumes that you are in the
southern hemisphere.
USA rules for Daylight Saving Time:
From 2007:
-
Start: Second Sunday in March
-
End: First Sunday in November