2. SERVICE TABLES

2.1 SERVICE PROGRAM MODE

NOTE: 4) [A294 I], [A295 I], [A294 II] and [A295 II] in the Settings column mean
the following product types:
[A294 I]: Existing 85 cpm model. [A295 I]: Existing 105 cpm model.
[A294 II]: Enhanced 85 cpm model. [A295 II]: Enhanced 105 cpm
model.
Mode No.
(Class 1, 2 and 3)
1-105
Fusing Temperature Adjustment
4
Fusing
Temperature
Correction
(A4/LT)
1-902
Web Motor Control
2
Web Motor
Drive Interval
3
Web Motor
Drive Time
SM
CÓPIA NÃO CONTROLADA
DIFFERENCES FROM THE A294 I / A295 I MODELS
Function
Specifies the amount to raise the fusing
temperature from standby mode to print on
paper of A4/LT width.
B
Change the interval of copy operation time
after which the web motor is driven
B
Changes the time that the web motor is
driven.
B
11-9
CÓPIA NÃO CONTROLADA
Settings
–5 ~ +20
1°C/step
[A294 I]
+10° ° ° ° C
[A295 I]
+15° ° ° ° C
[A294 II]
+5° ° ° ° C (US)
+10° ° ° ° C (EU)
[A295 II]
+5° ° ° ° C (US)
+15° ° ° ° C (EU)
[A294/A295 I]
15 ~ 130
1 s/step
[A294 I] 42 s
[A295 I] 34 s
[A294/A295 II]
3 ~ 130
1 s/step
[A294 II]
11 s (EU)
21 s (US)
[A295 II]
9 s (EU)
17 s (US)
[A294/A295 I]
0.1 ~ 3.0
0.1 s/step
0.8 s
[A294/A295 II]
0.3 ~ 3.5
0.1 s/step
2.8