Gestetner A294 Service Manual page 247

Table of Contents

Advertisement

Rev. 9/2001
Mode No.
(Class 1, 2 and 3)
2-974
Toner Supply Interval
3-001
ID Sensor Initial Setting
1
ID Sensor PWM
Setting
3-001
ID Sensor Initial Setting
2
Initialization
3-103
ID Sensor Output Display
1
V
SG
2
V
Initial
SG
(Designer Use)
3
V
SP
4
V
Initial
SP
(Designer Use)
3-901
Auto Process Control Setting
3-902
Process Control Data Display
1
Auto Process
Control
(O: OFF, 1: ON)
3-902
Process Control Data Display
2
V
D
3
Half Tone V
4
V
G
SM
CÓPIA NÃO CONTROLADA
Adjusts the interval of toner supply. (Once
every how many prints)
• The operation of SP2-968 has been
changed.
• The V
update interval has been
REF
changed from "every 100 prints" to
"every (100 X (SP2-974 value + 1))
prints".
This SP mode is added to recover the
machine when an SC condition occurs
because ID Sensor Initial Setting is not
done after doing an NVRAM Clear or
B
replacing the NVRAM. Reset this SP to the
factory setting in this case.
The PWM data is stored when ID Sensor
Initial Setting is done.
Performs the ID sensor initial setting. The
ID sensor output for the bare drum (V
adjusted to 4.0 ± 0.2 V.
B This SP mode should be performed after:
1. Replacing or cleaning the ID sensor
2. Replacing the NVRAM or doing an
NVRAM clear.
Displays the current V
If the ID sensor does not detect the ID
pattern, "V
= 5.0 V/V
SP
B
displayed and an SC code is generated.
If the ID sensor does not detect the bare
area of the drum, "V
is displayed and an SC code is generated.
Decides whether or not the machine
checks and corrects the drum potential
B
(V
) and LD power when the fusing
D
temperature is lower than 100°C at power-
up.
Displays whether auto process control is on
B
or off.
B Displays the drum potential.
Displays the drum potential in areas
H
B
illuminated by the laser during LD power
adjustment (auto process control).
Displays the charge grid voltage which
resulted from the latest V
B
4-25
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Function
) is
SG
and V
output.
SG
SP
= 5.0 V" is
SG
= 0.0 V/V
= 0.0 V"
SP
SG
adjustment.
D
Settings
0: 1/1 (every
print)
1: 1/2 (every 2
prints)
2: 1/3 (every 3
prints)
3: 1/4 (every 4
prints)
0 ~ 255
1/step
72
Start
ON
OFF
A294/A295

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

A295