SERVICE PROGRAM MODE
Mode No.
(Class 1, 2 and 3)
4-902
SBU Setting
53
Reference
Voltage
Adjustment
(Memory)
59
Standard White
Level
61
Range F
(Factory
Setting)
62
Gain
Adjustment -
First Side O ch
(Factory
Setting)
65
Range L
(Factory
Setting)
66
Gain F-O ch
(Factory
Setting)
67
Gain L/F ch
(Factory
Setting)
68
Gain L-O ch
(Factory
Setting)
71
Reference
Voltage
(Factory
Setting)
75
Overflow Flag
76
Time Out Flag
78
SBU Reset
Error Flag
79
Error Flag
80
E/O Adjustment
Error Count
SM
CÓPIA NÃO CONTROLADA
Checks the value of the standard white
level after adjusting the white level.
S
This SP mode is for factory use only.
Checks either the maximum or minimum
white shading data.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the EVEN channel of the first side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the ODD channel of the first side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the EVEN channel of the last side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the ODD channel of the last side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the EVEN channel of the last side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the AGC gain value of the white
level for the ODD channel of the last side
S
after adjusting the white level at power-up.
This SP mode is for designer use only.
Checks the value of the standard white
level after adjusting the white level.
S
This SP mode is for factory use only.
Checks the overflow flag data during the
automatic scanner adjustment.
This SP mode is for designer use only.
Checks the time out flag data during the
automatic scanner adjustment.
This SP mode is for designer use only.
Checks the error flag data during the
automatic scanner adjustment.
This SP mode is for designer use only.
Checks the error flag data during the
automatic scanner adjustment.
This SP mode is for designer use only.
Counts the errors during the automatic
scanner adjustment.
S
This SP mode is for designer use only.
4-30
CÓPIA NÃO CONTROLADA
Function
Rev. 9/2001
Settings
0 ~ 255
1/step
117
0: Maximum
1: Minimum
0 ~ 255
1/step
80
0 ~ 255
1/step
80
0 ~ 255
1/step
0
0 ~ 255
1/step
0
0 ~ 255
1/step
0
0 ~ 255
1/step
0
0 ~ 255
1/step
117
0 ~ 1023
1/step
0
0 ~ 1023
1/step
0
0 ~ 15
1/step
0
0 ~ 255
1/step
0
0 ~ 255
1/step
0