6.8.16 COPIER FEED UNIT/DEVELOPMENT FAN MOTOR
REMOVAL
A294R939.WMF
1. Turn off the main switch.
2. Remove the development unit. (Refer to Development Unit Removal.)
3. Remove the lower right inner cover. (Refer to Registration Sensor Cleaning.)
4. Draw out the duplex unit about 10 cm.
5. Remove the LCT relay motor. (Refer to LCT Relay Motor Removal.)
6. Remove the upper right cover. (See Exterior.)
7. Remove the two fan motors [A] (1 screw, 1 connector each).
8. Remove the copier feed unit [B] (5 screws, 2 connectors).
SM
CÓPIA NÃO CONTROLADA
[A]
6-77
CÓPIA NÃO CONTROLADA
PAPER FEED
[B]
A294R940.WMF