NOTE: 1) When re-installing parts, make sure that the feeler lever [A] for the web
end sensor is on the web as shown. Otherwise, after re-installing the
parts and turning on the main switch, web end (SC550) will be
displayed.
2) When putting back the oil supply and cleaning web assembly, make
sure that the flange for the bushings does not ride on the side edges [B]
of the oil supply and cleaning web unit cover.
3) If the web has a buckle between the web supply roll and web collecting
roll, turn the web collecting roller gear [C] clockwise (front view) until the
buckle is pulled straight.
8. Reassemble the fusing unit.
NOTE: Make sure that the web collecting roller gear engages with the gears on
the fusing unit exit unit after re-attaching the oil supply and cleaning
web unit.
9. Access SP1-902-1 (web consumption counter), and change the value to 0.
10. Perform reset procedure for level "A" service code.