Rev. 02/2000
6.11.4 ACCESS TO INSIDE THE TONER BANK
[C]
[A]
A294R947.WMF
NOTE: The toner bottle sensors and toner collection bottle sensor are inside
the toner bank.
1. Remove the toner bank (see Toner Bank Unit Removal).
2. Remove the toner release link bracket [A] (2 screws).
3. Remove the left side plate [B] (9 screws and 2 links [C]).
NOTE: When putting back the links [C], put the front pin [D] under the lock
plate [E].
4. Remove the toner bottle bottom plates [F] (3 screws each).