Cleaning Blade/Id Sensor Replacement - Gestetner A294 Service Manual

Table of Contents

Advertisement

DRUM UNIT

6.5.5 CLEANING BLADE/ID SENSOR REPLACEMENT

A294R558.WMF
1. Remove the drum. (Refer to Drum Unit Removal and Drum Replacement.)
2. Remove the cleaning blade [A] (2 screws).
3. Clean the side seals [B] and cleaning brush [C].
NOTE: When a vacuum cleaner is used, to protect the electrical parts from
static electricity, remove the ID sensor as follows:
1) Disconnect the 12-pin connector [D].
2) Separate the upper and lower drum units.
3) Remove the spur bracket [E] and pick-off pawl bracket [F] (2 screws).
4) Disconnect the connector [G].
5) Slide the pick-off pawl bracket to the rear, while turning it
4. Install the new cleaning blade.
NOTE: Do not clean the edge of the cleaning blade with a cloth; this damages
the edge and causes black lines on copies.
Do not touch the edge of the new cleaning blade. If some setting
powder or toner on the blade edge is removed, apply toner at that
place.
When installing the cleaning blade, do not pinch the side seals.
A294/A295
CÓPIA NÃO CONTROLADA
[B]
counterclockwise (as seen from the front). The ID sensor is on this
bracket.
NOTE: After installing a new ID sensor, do SP3-001-2.
CÓPIA NÃO CONTROLADA
[A]
[B]
[C]
6-38
Rev. 6/2000
[E]
[F]
[G]
A294R559.WMF
[D]
SM