25. Install the upper [A] (3 screws) and lower [B] (3 screws) covers of the operation
unit holder.
26. Set the dust filter [C] as shown.
27. Set the optics dust filter [D] as shown.
28. Loosen the two screws [E] of the bracket [F]. Then set the original exit tray [G].
29. Secure the original exit tray with 2 - M4 x 12 screws [H] and 1 M4 x 8 screw [I].
NOTE: Do not use these M4 x 12 screws for securing the other exterior covers.
They might hit a moving part inside the machine and damage that part.
30. Secure the bracket [F] to the operation unit arm with screw [I]. Then retighten
the two screws [E] to secure the bracket to the original exit tray.
31. Reinstall the right upper cover [J].
32. Plug in the power cord and turn the main switch on. Put toner bottle(s) in the
toner bank.