DIFFERENCES FROM THE A294 I / A295 I MODELS
SC591 (Toner Supply Motor Lock):
Detection:
The toner supply pump sensor status or development suction pump sensor
does not change for 1 second while drive is being supplied to one of the
pumps.
Possible causes:
• Toner supply pump or development suction pump defective
• Toner supply pump sensor or development suction pump sensor
defective
• BCU defective
3. Change in Photo Mode processing (Default Setting → Image Adjustment).
The image processing for Glossy Photo mode of Photo mode in the user tools
has been changed so that it produces a sharper image.
NOTE: No change made to any other modes.