Hot Roller Replacement - Gestetner A294 Service Manual

Table of Contents

Advertisement

FUSING UNIT

6.9.3 HOT ROLLER REPLACEMENT

[D]
[A]
A294R507.WMF
Remove the hot roller unit:
Follow steps 1 to 5 of hot roller unit removal and pressure roller replacement.
1. Remove the fusing entrance guide [A] (2 screws).
2. Remove the two screws [B] securing the harness terminal bracket, and unhook
the bracket.
NOTE: Unhook the thermistor cable [C] and thermofuse cable [D] to prevent
them from becoming damaged.
3. Disconnect the three green connectors [E] for the fusing lamp cables from the
terminal on the rear side.
4. Disconnect the three white fusing lamp connectors [F] on the front side.
NOTE: To distinguish the 630W (A295) from the 530W (A294) lamps, the color
of the front wire harness [G] of the fusing lamp for the 630W (A295) is
different from that of the 530W (A294).
A294: 530W, Blue
A295: 630W, Red
The colors of the connectors for both the lamps are the same. The following note
for re-assembling does not change.
A294/A295
CÓPIA NÃO CONTROLADA
[C]
[F]
[B]
6-86
CÓPIA NÃO CONTROLADA
[E]
[G]
Rev. 6/2000
[E]
A294R508.WMF