6.5.6 CLEANING BRUSH REPLACEMENT

[C]
1. Remove the cleaning blade. (Refer to Cleaning Blade Replacement.)
2. Remove the coupling gear [A] (1 screw).
3. Remove the bushing [B] (1 screw).
4. Pull the cleaning brush shaft to the rear to release the cleaning brush [C], then
remove the cleaning brush.
NOTE: Do not touch the cleaning brush with bare hands.
After replacement, clean the ID sensor surface. Then do SP3-001-2 to
initialize the sensor.
SM
CÓPIA NÃO CONTROLADA
6-39
CÓPIA NÃO CONTROLADA
DRUM UNIT
[B]
[A]
A294R204.WMF
A294/A295