Rev. 9/2001
Mode No.
(Class 1, 2 and 3)
7-801
ROM Version Display
7-803
PM Counter Display
7-804
PM Counter Reset
7-807
SC/Jam Counter Reset
7-808
Counter Clear
7-810
Access Code Clear
7-816
Copy Counter Clear- Paper Tray
1
Paper Tray 1
2
Paper Tray 2
3
Paper Tray 3
4
Paper Tray 4
5
Paper Tray 5
6
Paper Tray 6
7-817
Total ADF Counter Reset
7-822
Copy Counter Clear - Magnification
7-825
Total Counter Clear
7-826
Option Counter Error Counter
1
Total
2
Staple
7-827
Option Counter Error Counter Clear
7-828
Punch Counter Clear
SM
CÓPIA NÃO CONTROLADA
Function
Displays the ROM versions.
001: SICU
002: BCU
003: CSS (P1) – Japan only
004: HDC (Hard disk controller)
005: Scanner
006: ADF
007: Finisher
008: Printer
S Displays the PM counter since the last PM.
Resets the PM counter.
Resets the SC and jam counters. Press
"Start" to reset.
Resets all counters, except for the total
counters (SP 7-003):
Press "Start" to reset.
Resets both the key operator code and the
weekly timer code ('key operator code for
off setting'). Press "Start" to reset.
Resets the total copy counter by paper
tray. These SP modes can be used after
replacing the pick-up, feed, and separation
rollers in the paper feed stations.
Resets the ADF Counter (SP7-205). Press
"Start" to reset.
Resets all counters of SP7-301.
Resets the electrical total counter.
Usually, this SP mode is done at
installation.
This SP mode works only once when the
counter value is negative.
S
For Japanese version only.
S
For Japanese version only.
Resets the punch counter (SP7-207)
4-58e
4-63
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Settings
Start
Start
Start
Start
Start
Start
Start
Start
A294/A295