4.3 ALIGNMENT BRUSH ROLLER REPLACEMENT

[B]
[D]
B302R507.WMF
1. Open the front door and pull out the staple unit.
2. Remove the rear cover.
3. Remove the screw [A] and a tension spring [B] for the tension bracket [C], and
release the tension of the timing belt.
4. Remove the pulley [D] and ball bearing [E] (1 E-ring each).
5. Remove screw [F] of the inner cover [G].
6. Open the guide [H] and a part of the inner cover, and remove the alignment
brush roller assembly [I] (1 E-ring).
7. Replace the alignment brush roller (1 E-ring, 1 ball bearing).
SM
CÓPIA NÃO CONTROLADA
ALIGNMENT BRUSH ROLLER REPLACEMENT
[C]
[A]
[E]
[I]
8-25
CÓPIA NÃO CONTROLADA
[H]
[F]
[G]
B302R508.WMF