Gestetner A294 Service Manual page 502

Table of Contents

Advertisement

FIRMWARE HISTORY
DESCRIPTION OF MODIFICATION
6. SC 495 Prevention
When only one toner bottle is set and a long
job is done using high image density original,
the system toner end is not detected and
SC495 is displayed.
7. SC 495 Prevention (at installation)
Enough toner was not supplied to the toner
hopper when performing SP2-207 at
installation.
The toner supply time in SP2-207 has been
extended
Details of Errors and modification
(Ver. 7.19)
1. SP6-113 Error
SP6-113 setting is reset when the main switch
is turned off and on if the value is changed to
minus area.
2. SC515 Prevention
SC515 was displayed if the main switch is
turned off and on when the tandem rear fence
is fully shifted to the right.
This occurs because the machine recognized
that the end fence is between the Rear Fence
Return Position sensor and the Rear Fence
HP Sensor even if the end fence is at the right
side of the Rear Fence Return Position
sensor.
To counter this, the rear fence is moved to the
left for 1 second if both sensors do not detect
the fence when the main switch is turned on.
3. SP6-119 description correction
The description was incorrect.
Incorrect:
0: Enabled
1: Disabled
Corrected: 0: Disabled
1. Enabled
4. SMC Print Missing Items
The following SP modes were not printed out
by SMC print:
SP5-038
SP5-212-3, 4
SP5-967
5. 1st Tray Movement Error
After moving tandem end fence using SP5-
804, the 1st tray does not work until the main
switch is turned off and on.
A294/A295
CÓPIA NÃO CONTROLADA
A294 / A295 FIRMWARE MODIFICATION HISTORY
CÓPIA NÃO CONTROLADA
FIRMWARE
SERIAL
LEVEL
NUMBER
A2945610 D
From Feb, 00
production
7-44
Rev. 10/2000
FIRMWARE
VERSION
7.19
Continued..