Gestetner A294 Service Manual page 471

Table of Contents

Advertisement

Rev.9/2001
SC360: Hard Disk Drive Error 1
Definition [B]
The machine does not detect the connection signal from HDD 1 when the main
switch is turned on.
Possible Causes
• Poor connection between the HDD and SICU
• The dc power connector to the HDD is disconnected
• HDD defective
• SICU defective
SC361: Hard Disk Drive Error 2
Definition [C]
The machine does not detect the connection signal from HDD 2 when the main
switch is turned on.
Possible Causes
• Poor connection between the HDD and SICU
• The dc power connector to the HDD is disconnected
• HDD defective
• SICU defective
SC362: Hard Disk Drive Error 3
Definition [C]
The machine does not detect the connection signal from HDD 1 when the
operation switch is turned on.
Possible Causes
• Poor connection between the HDD and SICU
• The dc power connector to the HDD is disconnected
• HDD defective
• SICU defective
SC363: Hard Disk Drive Error 4
Definition [C]
The machine does not detect the connection signal from HDD 2 when the
operation switch is turned on.
Possible Causes
• Poor connection between the HDD and SICU
• The dc power connector to the HDD is disconnected
• HDD defective
• SICU defective
SM