6.9.10 FUSING PRESSURE ADJUSTMENT

Adjustment standards: Nip width 11.5 ± 0.5 mm (the difference between front and
rear measurements should be less than 0.5 mm).
1. Select the fusing nip band check mode (SP1-109).
2. Make a copy using an A4/LT OHP sheet. Copying will start. It will stop in the
fusing unit for 30 seconds and then will exit.
NOTE: If an OHP sheet is not available, use a solid black copy on plain paper
(make the copy with the ADF open – the copy will be all black).
3. Measure the nip band width (the shiny band) at both ends.
4. It the nip band width is not within specifications at both ends, release the fusing
pressure and adjust it using the adjustment screw [A] (clockwise = increases
the pressure, counterclockwise = decreases the pressure).
NOTE: Loosen the lock nuts [B] before turning the pressure adjustment screw.
Re-tighten the nuts after adjusting.
5. Repeat steps 1 to 4 to confirm the nip band width.
SM
CÓPIA NÃO CONTROLADA
[A]
[B]
6-95
CÓPIA NÃO CONTROLADA
FUSING UNIT
A294R056.WMF
A294/A295