BOARDS AND OTHER ITEMS
6.12.7 FUSING/DUPLEX MOTOR REPLACEMENT
[A]
1. Remove the upper rear cover.
2. Swing out the BCU board. (Refer to the BCU board replacement procedure)
3. Loosen screw [A] to release the belt tension.
4. Remove the timing belt [B].
5. Remove the fusing/duplex motor [C] (4 screws, 2 hooks [D]).
NOTE: When putting back the parts, hook up the tension spring (this
automatically gives the belt the correct tension), then tighten screw [A].
A294/A295
CÓPIA NÃO CONTROLADA
[B]
6-116
CÓPIA NÃO CONTROLADA
[C]
A294R921.WMF
Rev. 02/2000
[D]