Protection/Maintenance Mode Selection Function

Main circuit capacitor life judgment selection, main circuit capacitor life judgment, inrush current pre-
vention resistor overheat detection, and braking transistor broken detection operations can be select-
ed and set as combined operations.
Parameter No.
3008Hex-63He
x
Set function settings as binary values to their respective bits, and set the resulting data as decimal
data to Protection/Maintenance Function Mode Selection (3008Hex-63Hex).
The following shows the settings of each bit and each function.
Bit
Bit 0 to 2
Bit 3
Bit 4
Bit 5
M1 Series EtherCAT Type User's Manual (I670)
Function name
Input Terminal Monitor
Function name
Communication Data Terminal
[DO]
Function name
Protection/Maintenance Function
Mode Selection
Function
Reserved
Main circuit capacitor life judgment stand-
ards selection
Judge main circuit capacitor life
Detect inrush current prevention resistor
overheat
Data
Bit15: -
Bit14: -
Bit13: -
Bit12: EN2
Bit11: EN1
Bit10: -
Bit9: -
Bit8: -
Bit7: -
Bit6: DI5
Bit5: DI4
Bit4: DI3
Bit3: DI2
Bit2: DI1
Bit1: DI7
Bit0: DI6
Data
Bit8: RO
Bit0: DO1
Data
0 to 255
Data = 0
-
Default value
Disable
Enable
8 Other Functions
Default da-
Unit
ta
0
-
Default da-
Unit
ta
0
-
Default
Unit
data
80
-
Data = 1
-
User setting
Enable
Disable
8-141