Event name
Motor Overload Warning
Meaning
The current value reached the overload warning level.
Source
EtherCAT Master Function Mod-
ule
Error attrib-
Level
utes
Effects
User program
Indicators
EtherCAT NET RUN
---
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
(1) Motor overload warning
Attached in-
None
formation
Precautions/
None
Remarks
M1 Series EtherCAT Type User's Manual (I670)
Source details Slave
Observation
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
None
Correction
→ Check if the current flow is
more than the current value set
in 1st Overload Early Warning
Detection Level (3005-26 hex),
2nd Overload Warning
Detection Level (3005-38 hex),
and Overload early warning 2
Level (3005-23 hex).
Event code
68460000 hex
Detection tim-
ing
Automatic re-
Log category
covery
Not affected.
EtherCAT LINK/ACT
---
Name
None
Prevention
Set 1st Overload Early Warning
Detection Level (3005-26 hex),
2nd Overload Warning
Detection Level (3005-38 hex),
and Overload early warning 2
Level (3005-23 hex) appropriate-
ly.