Omron M1 Series User Manual page 374

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

8 Other Functions
Parameter No.
3011Hex-45Hex
301AHex-13Hex
3 Second last alarm
3012Hex-01Hex
3012Hex-02Hex
3012Hex-06Hex
3012Hex-07Hex
3012Hex-09Hex
301AHex-1DHex
4 Third last alarm
3012Hex-33Hex
3012Hex-34Hex
3012Hex-38Hex
3012Hex-39Hex
3012Hex-3BHex
301AHex-27Hex
5 Fourth last alarm
301AHex-2AHex
301AHex-2BHex
8-20
Item
Last Alarm Info. Main Cir-
cuit DC Voltage
Last Alarm Info. Cumula-
tive Running Time
Second Last Alarm Info.
Output Frequency
Second Last Alarm Info.
Output Current
Second Last Alarm Info.
Running Status
Second Last Alarm Info.
Cumulative Ope. Time
Second Last Alarm Info.
Main Circuit DC Voltage
Second last Alarm Info.
Cumulative Running Time
Third Last Alarm Info. Out-
put Frequency
Third Last Alarm Info. Out-
put Current
Third Last Alarm Info. Run-
ning Status
Third Last Alarm Info. Cu-
mulative Ope. Time
Third Last Alarm Info. Main
Circuit DC Voltage
Third last Alarm Info. Cu-
mulative Running Time
Fourth last Alarm Info. Out-
put Frequency
Fourth last Alarm Info. Out-
put Current
Range
The Main Circuit DC Voltage of the in-
0.0 to 999.0 [V]
verter is displayed.
The cumulative time of the inverter
0 to 655,350 hours
RUN state is displayed.
The output frequency before slip com-
0.00 to 99.99,
pensation is displayed in increments of
100.0 to 590.0
0.01 Hz. A value of 100.0 Hz or higher
[Hz]
is displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
0.00 to 99.99,
rent value of 100.0A or higher is dis-
100.0 to 655.3 [A]
played in increments of 0.1 A.
Display unit: A (Ampere)
0000Hex to
The operation status is displayed by a
FFFFHex
four-digit hexadecimal.
The number of operations of the motor
(number of times the RUN command for
0 to 655,350 hours
the inverter is turned ON) is calculated
and displayed.
The Main Circuit DC Voltage of the in-
0.0 to 999.0 [V]
verter is displayed.
The cumulative time of the inverter
0 to 655,350 hours
RUN state is displayed.
The output frequency before slip com-
0.00 to 99.99,
pensation is displayed in increments of
100.0 to 590.0
0.01 Hz. A value of 100.0 Hz or higher
[Hz]
is displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
0.00 to 99.99,
rent value of 100.0A or higher is dis-
100.0 to 655.3 [A]
played in increments of 0.1 A.
Display unit: A (Ampere)
0000Hex to
The operation status is displayed by a
FFFFHex
four-digit hexadecimal.
The number of operations of the motor
(number of times the RUN command for
0 to 655,350 hours
the inverter is turned ON) is calculated
and displayed.
The Main Circuit DC Voltage of the in-
0.0 to 999.0 [V]
verter is displayed.
The cumulative time of the inverter
0 to 655,350 hours
RUN state is displayed.
The output frequency before slip com-
0.00 to 99.99,
pensation is displayed in increments of
100.0 to 590.0
0.01 Hz. A value of 100.0 Hz or higher
[Hz]
is displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
0.00 to 99.99,
rent value of 100.0A or higher is dis-
100.0 to 655.3 [A]
played in increments of 0.1 A.
Display unit: A (Ampere)
M1 Series EtherCAT Type User's Manual (I670)