Event name
Magnetic Pole Position Detection Error
Meaning
In synchronous motor vector control with sensor, a magnetic pole position detection error occurred.
Source
EtherCAT Master Function Mod-
ule
Error attrib-
Level
utes
Effects
User program
Indicators
EtherCAT NET RUN
---
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
(1) Inverter settings are not ap-
propriate.
M1 Series EtherCAT Type User's Manual (I670)
Source details Slave
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Confirm that the motor, and the
presence/absence and type of
speed/magnetic pole position
sensor, are consistent with the
settings of 1st Drive control
selection (3004-2B hex),
Terminal [PIA][PIB] Pulse input
format (3014-0F hex), and
Terminal [PIA][PIB] Encoder
pulse resolution (3014-10 hex).
→ Confirm the machine configu-
ration (the motor, and the type
and specifications of and speed/
magnetic pole position sensor)
and correctly set 1st Drive
control selection (3004-2B
hex), Terminal [PIA][PIB] Pulse
input format (3014-0F hex), and
Terminal [PIA][PIB] Encoder
pulse resolution (3014-10 hex).
Check if 1st PM motor drive
magnetic pole position
detection mode (3007-1F hex)
is set to 0 or 3 and 1st PM
motor magnetic pole position
sensor offset (3007-60 hex) is
not 999 (Offset not adjusted).
→ Correctly set the 1st PM
motor magnetic pole position
sensor offset (3007-60 hex).
(Auto-tuning is also possible. Re-
fer to 7-8-1 Motor Off-line Auto-
tuning on page 7-65.)
Event code
38A60000 hex
Detection tim-
ing
Error reset
Log category
Motor stops.
EtherCAT LINK/ACT
---
Name
None
Prevention
Wire and set up the inverter ap-
propriately.
Appendices