Omron M1 Series User Manual page 758

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

Appendices
Event code
Event name
08870000 hex
2nd Motor
Overload
Protection
08880000 hex
Thermistor
Error
A-212
Description
Motor 2 is overloaded. (1) The characteristics of the
electronic thermal and the
overload characteristics of the
motor do not match.
(2) The operation level of the
electronic thermal is not ap-
propriate.
(3) The acceleration/decelera-
tion time is short.
(4) The load is large.
(5) The value of Torque
Boost Voltage (3004-0A hex,
3009-06 hex) is too high.
The motor's internal
(1) The motor's ambient tem-
temperature became
perature exceeds the specified
abnormally high.
range.
(2) The motor's cooling sys-
tem failed.
(3) The load is large.
(4) The value of 1st
Thermistor level (3008-1C
hex) is not appropriate.
(5) The PTC thermistor set-
tings are not appropriate.
(6) The value of Torque
Boost Voltage (3004-0A hex,
3009-06 hex) is too high.
(7) The V/f settings are incor-
rect.
(8) There is an incorrect pa-
rameter setting.
Assumed cause
Min
M1 Series EtherCAT Type User's Manual (I670)
Level
Reference
Obs
Info
page
A-253
page
A-255

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents