Maintenance Monitor - Omron M1 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

8 Other Functions
Power ON Time Over (236: ONT)
• Allocate "236: ONT" to Output Terminal [DO1] Function Selection (3005Hex-15Hex) and Output Ter-
minal [ROA, ROB] Function Selection (3005Hex-1CHex).
• The power ON time of the inverter's main circuit is counted and output to Cumulative Operation
Time (3003Hex-15Hex). When RUN Time Over (RNT)/Power ON Time Over (ONT) Detection Level
(301FHex-37Hex) elapses, the ONT terminal (236: Power ON time over) turns ON.
RUN time over (238: RNT)
• Allocate "238: RNT" to Output Terminal [DO1] Function Selection (3005Hex-15Hex) and Output Ter-
minal [ROA, ROB] Function Selection (3005Hex-1CHex).
• Time is measured during inverter operation (inverter output signal (35: RUN2) is ON) and the result
is output to Total RUN Time Monitor (3017Hex-50Hex). When RUN Time Over (RNT)/Power ON
Time Over (ONT) Detection Level (301FHex-37Hex) elapses, RNT terminal (237: RUN time over)
turns ON.
8-8-8

Maintenance monitor

The Maintenance timer counted up (MNT) signal is output when the cumulative operation time for mo-
tor 1 exceeds the preset time, or when the number of startups for motor 1 exceeds the preset number
of times.
Parameter No.
3008Hex-4FHex
3008Hex-5FHex/
3009Hex-34Hex
3008Hex-50Hex
3008Hex-2DHex/
3009Hex-35Hex
3005Hex-15Hex/
3005Hex-1CHex
Maintenance Timer (3005Hex-15Hex, 3005Hex-1CHex = 84: MNT)
Allocate "84: MNT (Maintenance timer counted up)" to Output Terminal [DO1] Function Selection
(3005Hex-15Hex) and Output Terminal [ROA, ROB] Function Selection (3005Hex-1CHex).
The signal is output when 1st Startup Count for Motor (3008Hex-2DHex) reaches the value set at 1st
Preset Startup Count for Motor Maintenance (3008Hex-50Hex), or 1st Cumulative Motor Run Time
(3008Hex-5FHex) reaches the value set at 1st Motor Maintenance Interval (3008Hex-4FHex).
8-82
Function name
1st Motor Maintenance Inter-
val
1st Cumulative Motor Run
Time/2nd Cumulative Motor
Run Time
1st Preset Startup Count for
Motor Maintenance
1st Startup Count for Motor/
2nd Startup Counter for Mo-
tor
Output Terminal [DO1] Func-
tion Selection/
Output Terminal [ROA, ROB]
Function Selection
Data
0: Disable
1 to 9999 (in 10 hours)
0 to 9999 (in 10 hours)
0: Disable
1 to 65,535
0 to 65,535
84: MNT (Maintenance timer
counted up)
M1 Series EtherCAT Type User's Manual (I670)
Default data
Unit
8760
Hours
0
Hours
0
-