Omron M1 Series User Manual page 706

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

Appendices
Sub-
Pa-
Index
index
rame-
(hex)
(hex)
ter No.
25
J136
26
J137
27
J138
*1.
For SDO communications and PDO communications, it is 7FFF hex.
A-4-14 d Group Parameter List (Applied Functions 2)
Sub-
Pa-
Index
index
rame-
(hex)
(hex)
ter No.
3014
02
d01
03
d02
04
d03
05
d04
06
d05
07
d06
08
d07
A-160
Function name
Monitor or data range
PID Control Mul-
V/f
tistep PID Com-
SLV
mand 1
-999.00 to 9,990.00
PID Control Mul-
tistep PID Com-
mand 2
PID Control Mul-
tistep PID Com-
mand 3
Function name
Monitor or data range
Speed Control 1
V/f
Speed Command
SLV
Filter
0.000 to 5.000
Speed Control 1
V/f
Speed Detection
SLV
Filter
0.000 to 0.100
Speed Control 1
V/f
P Proportional
SLV
Gain
0.1 to 200.0
Speed Control 1 I
V/f
Integral Time
SLV
0.001 to 9.999
999: Disable
Speed Control 1
V/f
FF Gain
SLV
0.00 to 99.99
Speed Control 1
V/f
Output Filter
SLV
0.000 to 0.100
Speed Control 1
V/f
Notch Filter Res-
SLV
onance Frequen-
1 to 500
cy
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
DTV
PG V/f PG DTV
PGV PM SLV PM PGV
M1 Series EtherCAT Type User's Manual (I670)
Set-
ting
Default
dur-
Unit
data
ing
RUN
0
---
Possible
Set-
ting
Default
dur-
Unit
data
ing
RUN
0.02
s
Possible
0.005
s
Possible
10
---
Possible
0.1
s
Possible
0
s
Possible
0.002
s
Possible
200
Hz
Possible
PDO
map
PDO
map

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents