Born to drive machines; 200 v class three-phase input 0.1 to 15 kw; 200 v class single-phase input 0.1 to 2.2 kw; 400 v class three-phase input 0.4 to 15 kw (53 pages)
Born to drive machines • Current vector control • High starting torque: 200% at 0.5 Hz • Double rating VT 120%/1 min and CT 150%/1 min • Speed range up to 1000 Hz • IM & PM motor control • Torque control in open loop vector •...
50%: feedback <60Hz Forced-air-cooling Self cooling Cooling method Three phase model use forced-air-cooling but single phase model is self cooling. Based on a standard 3-Phase standard motor. Above 400 Hz with some function limitation. 400 V class Three-phase: MX2@ A4004...
Page 3
SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re- mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multi-stage speed setting;...
Function (signal level) Main circuit power supply input Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal R/L1, S/L2, T/L3 S/L2 is not available for these units...
Control Circuit Type Signal name Function Signal level Source type: connecting [P24] to [1]-[7] turns inputs ON Intelligent input common Sink type: connecting [L] to [1]-[7] turns inputs ON Internal 24 VDC 24 VDC, 30mA 24 VDC, 30 mA Multi-function Input selection 1...
Page 9
96.6 Forced-air-cooling Cooling Method Self cooling Input AC Reactor AC reactor Power supply MCCB R/L1 S/L2 T/L3 3 phase 200 V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance Reference Reference motor output kW...
DC reactor Motor Output AC reactor Ground Specifications Model Variable torque Constant torque Voltage class Standard Max motor kW Rated current A Max motor kW Rated current A MX2-AB001-E MX2-AB002-E 0.55 MX2-AB004-E Single-phase 200 V 0.75 MX2-AB007-E MX2-AB015-E 11.0 12.0...
Page 11
Types Model Description Functions AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m. 3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator 3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m...
Page 12
Configuration and monitoring software tool ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.