Omron MX2 Product Information

Omron MX2 Product Information

Mx2 series
Hide thumbs Also See for MX2:

Advertisement

MX2
Born to drive machines
• Current vector control
• High starting torque: 200% at 0.5 Hz
• Double rating VT 120%/1 min and CT 150%/1 min
• Speed range up to 1000 Hz
• IM & PM motor control
• Torque control in open loop vector
• Positioning functionality
• Built-in application functionality (i.e. Brake control)
• User programmable as standard
• Safety embedded compliant with ISO13849-1 (double input
circuit and external device monitor EDM)
• USB port for PC programming
• 24 VDC backup supply for control board
• Fieldbus communications: Modbus, DeviceNet, Profibus,
Componet, Ethercat, ML-II and CanOpen
• PC configuration tool: CX-Drive
• RoHS, CE, cULus
Ratings
• 200 V Class single-phase 0.1 to 2.2 kW
• 200 V Class three-phase 0.1 to 15.0 kW
• 400 V Class three-phase 0.4 to 15.0 kW

System configuration

Power
supply
MCCB
Input AC reactor
Filter
MX2
Choke
Motor
Ground
MX2
USB cable
Remote operator
extension cable
Communication option board
Braking resistor
DC reactor
Output AC reactor
CX-Drive
CX-One
LCD 5 lines remote
operator
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron MX2

  • Page 1: System Configuration

    Born to drive machines • Current vector control • High starting torque: 200% at 0.5 Hz • Double rating VT 120%/1 min and CT 150%/1 min • Speed range up to 1000 Hz • IM & PM motor control • Torque control in open loop vector •...
  • Page 2: Specifications

    50%: feedback <60Hz Forced-air-cooling Self cooling Cooling method Three phase model use forced-air-cooling but single phase model is self cooling. Based on a standard 3-Phase standard motor. Above 400 Hz with some function limitation. 400 V class Three-phase: MX2@ A4004...
  • Page 3 SET (set second motor), 2CH (2-stage accel./decel. command), FRS (free run stop command), EXT (external trip), USP (startup function), CS (commercial power switchover), SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermistor thermal protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID reset), UP (re- mote control up function), DWN (remote control down function), UDC (remote control data clear), OPE (operator control), SF1~SF7 (multi-stage speed setting;...
  • Page 4 Dimensions φ 4.5 φ 2-d φ 2-d ‚r‚x‚r‚c‚q‚h‚u‚d ‚r‚x‚r‚c‚q‚h‚u‚d ‚q‚t‚m ‚q‚t‚m ‚o‚v‚q ‚o‚v‚q ‚q‚t‚m ‚q‚t‚m ‚o‚v‚q ‚o‚v‚q ‚R‚f‚R‚l‚w‚Q ‚R‚f‚R‚l‚w‚Q ?@ ?@‚h‚m‚u‚d‚q‚s‚d‚q ‚h‚m‚u‚d‚q‚s‚d‚q ‚R‚f‚R‚l‚w‚Q ‚R‚f‚R‚l‚w‚Q ?@ ?@‚h‚m‚u‚d‚q‚s‚d‚q ‚h‚m‚u‚d‚q‚s‚d‚q ‚g‚š ‚g‚š ‚`‚k‚l ‚`‚k‚l ‚g‚š ‚g‚š ‚`‚k‚l ‚`‚k‚l ‚` ‚` ‚o‚q‚f ‚o‚q‚f ‚` ‚` ‚o‚q‚f...
  • Page 5: Option Board

    AX-RAI00740335-DE 180 DC Reactor Dimensions Weight Voltage Reference AX-RC21400016-DE 1.22 AX-RC10700032-DE AX-RC06750061-DE 1.60 AX-RC03510093-DE 1.95 AX-RC02510138-DE AX-RC01600223-DE 108 135 124 120 3.20 200 V AX-RC01110309-DE 5.20 120 152 6.00 AX-RC00840437-DE AX-RC00590614-DE 11.4 150 177 160 115 AX-RC00440859-DE 182. 14.3 1.22...
  • Page 6: Resistor Dimensions

    Dimensions Weight Voltage Reference AX-RAO16300038-DE 120 1.78 AX-RAO11800053-DE 120 2.35 AX-RAO07300080-DE 120 2.35 400 V AX-RAO04600110-DE 180 AX-RAO03600160-DE 180 AX-RAO02500220-DE 180 AX-RAO02000320-DE 180 11.7 Chokes Reference Motor Dimensions Weight Ø m diameter AX-FER2102-RE < 2.2 AX-FER2515-RE < 15 AX-FER5045-RE < 45 Ø...
  • Page 7: Standard Connections

    Function (signal level) Main circuit power supply input Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal R/L1, S/L2, T/L3 S/L2 is not available for these units...
  • Page 8: Control Circuit

    Control Circuit Type Signal name Function Signal level Source type: connecting [P24] to [1]-[7] turns inputs ON Intelligent input common Sink type: connecting [L] to [1]-[7] turns inputs ON Internal 24 VDC 24 VDC, 30mA 24 VDC, 30 mA Multi-function Input selection 1...
  • Page 9 96.6 Forced-air-cooling Cooling Method Self cooling Input AC Reactor AC reactor Power supply MCCB R/L1 S/L2 T/L3 3 phase 200 V class 400 V class Max. applicable Current value Inductance Max. applicable Current value Inductance Reference Reference motor output kW...
  • Page 10: Ordering Information

    DC reactor Motor Output AC reactor Ground Specifications Model Variable torque Constant torque Voltage class Standard Max motor kW Rated current A Max motor kW Rated current A MX2-AB001-E MX2-AB002-E 0.55 MX2-AB004-E Single-phase 200 V 0.75 MX2-AB007-E MX2-AB015-E 11.0 12.0...
  • Page 11 Types Model Description Functions AX-OP05-E LCD remote operator 5 Line LCD remote operator with copy function, cable length max. 3m. 3G3AX-CAJOP300-EE Remote operator cable 3 meters cable for connecting remote operator 3G3AX-OP01 LED remote operator LED remote operator, cable length max. 3m...
  • Page 12 Configuration and monitoring software tool ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.

Table of Contents