RST: Alarm reset
FWD: Forward command
REV: Reverse command
(All bits are ON with 1 regardless of the positive/negative logic setting.)
Example: Operation command (3002-07 hex) = FWD, DI1 = ON
0000 0000 0000 0101
Data Format [15]: General-purpose Output Terminal
15
14
13
0
0
0
RO: Relay output
FWD: Forward command
REV: Reverse command
(All bits are ON with 1 regardless of the positive/negative logic setting.)
Example: Output Terminal Monitor (3003-10 hex) DO1 = ON
0000 0000 0000 0001
Data Format [16]: Operation Status
15
14
13
BUSY
0
0
Not used
Operation status
(All bits are ON or active with 1.)
Bit
Symbol
0
FWD
1
REV
2
EXT
3
INT
4
BRK
5
NUV
6
TL
7
VL
Example: Operation Status 1 Monitor (3003-0F hex) = During forward operation and during acceler-
ation
M1 Series EtherCAT Type User's Manual (I670)
= 0005 hex →
00
Hex
b
12
11
10
9
8
0
0
0
0
0
Not used
General-purpose output
= 0001 hex →
00
Hex
b
12
11
10
9
RL
ALM
DEC ACC
IL
Description
During forward operation
During reverse operation
Direct DC braking
(or during pre-exciting)
Inverter shut down
During braking
Main circuit DC voltage estab-
lished
(Undervoltage with 0)
Torque limiting
During voltage limiting
05
Hex
7
6
5
4
RO
0
0
0
Not used
01
Hex
8
7
6
5
4
VL
TL
NUV BRK INT
Operation status
Bit
Symbol
8
IL
9
ACC
10
DEC
11
ALM
12
RL
13
0
14
0
15
BUSY
Appendices
3
2
1
0
0
0
DO2 DO1
General-purpose output
3
2
1
0
EXT REV FWD
Description
During current limiting
During acceleration
During deceleration
Alarm relay
Communications effective
---
---
During parameter code data
writing