Omron M1 Series User Manual page 484

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

8 Other Functions
Parameter No.
3014Hex-0FHex
3014Hex-10Hex
3014Hex-11Hex
3014Hex-12Hex
3014Hex-13Hex
3010Hex-38Hex
3010Hex-39Hex
3017Hex-28Hex
Related function
• Pulse train input method (3014Hex-0FHex)
By entering a pulse train in the input terminals [PIA] and [PIB] of the inverter control circuit, it is pos-
sible to make a frequency setting proportional to the frequency of the pulse. The pulse train input
method is specified by the Input Terminal [PIA][PIB] Pulse Input Format Selection (3014Hex-0FHex).
Input can be made in four types, namely the Pulse train signing/pulse train input, Forward and re-
verse pulse, and Quadrature A/B signal (A phase lead, B phase lead).
3014He
x-0FHex
Target terminal
data
Input Terminal [PIA]
0
Input Terminal [PIB]
8-130
Function name
Input Terminal [PIA][PIB] Pulse
Input Format Selection
Input Terminal [PIA][PIB] Encod-
er Pulse Resolution
Input Terminal [PIA][PIB] Pulse
Scaling Factor Denominator
Input Terminal [PIA][PIB] Pulse
Scaling Factor Numerator
Input Terminal [PIA][PIB] Pulse
Train Filter Time Constant
Pulse Input (A/B Phase [PIA]
[PIB])
Pulse Input (Z Phase [PIZ])
Pulse Train Frequency Monitor
Pulse input
method
Pulse train sign-
ing
Pulse train input
Data
0: Pulse train signing/pulse
train input
1: Forward/reverse rotation
pulse
2: Quadrature A/B signal
(B phase lead)
3: Quadrature A/B signal
(A phase lead)
20 to 60000
1 to 32767
1 to 32767
0.000 to 5.000
-327.68 to 327.67
0 to 16000
-163.84 to 163.83
Frequency Calculation Operation Target 1
(301FHex-20Hex)
Frequency Calculation Operation Target 2
(301FHex-21Hex)
Frequency Addition Sign Selection
(301FHex-24Hex)
Remarks
A speed command corresponding to the frequency of
pulse train input is applied. Moreover, the polarity of the
speed command can be set by the pulse train signing.
Forward
Pulse train
OFF
signing
Pulse train
input
M1 Series EtherCAT Type User's Manual (I670)
Default da-
Unit
ta
2
-
1024
pulse
1
-
1
-
0.005
s
-
kp/s
-
p/s
-
%
Reverse
ON