Omron M1 Series User Manual page 372

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

8 Other Functions
Parameter No.
3011Hex-25Hex
3011Hex-26Hex
8-18
Item
Latest Alarm Info. Running
Status 2
Latest Alarm Info. Speed
Detection
Range
The running status 2 is displayed by a
four-digit hexadecimal.
0000 to FFFF hex
Bit15: Motor type (1: PM motor / 0: In-
duction motor)
Bit14: During EN circuit diagnosis
Bit7: During speed control (1 during
control)
Bit5 Bit4: Select motor
00: 1st motor
01: 2nd motor
10: Reserved
11: Reserved
Bit3 to Bit0: Control method
0000Hex to
0000: V/F control without slip compen-
FFFFHex
sation
0001: Dynamic torque vector control
0010: V/F control with slip compensa-
tion
0011: V/F control with speed sensor
0100: Dynamic torque vector control
with speed sensor
0101: Vector control without speed sen-
sor
0110: Vector control with speed sensor
0111: Torque control (Vector control
without speed sensor)
1000: Torque control (Vector control
with speed sensor)
The speed detection value is displayed.
The speed detection value with ±maxi-
B1E0(-fmax) to
mum frequency = ±20000 expressed in
4E20(fmax)
hexadecimal is displayed in increments
of ±0.01 Hz.
M1 Series EtherCAT Type User's Manual (I670)
Display item

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents